ASTM C1244 PDF

ASTM C() Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test Prior to Backfill Paperback – April 1. ASTM A/AMa Testing Mechanical Splices for Steel Reinforcing Bars .. ASTM C Concrete Sewer Manholes by the Negative Air Pressure. This standard is issued under the fixed designation C; the 1 This test method is under the jurisdiction of ASTM Committee C13 on.

Author: Grorn JoJolrajas
Country: Puerto Rico
Language: English (Spanish)
Genre: Medical
Published (Last): 20 January 2004
Pages: 477
PDF File Size: 10.9 Mb
ePub File Size: 7.34 Mb
ISBN: 833-5-31262-647-7
Downloads: 86156
Price: Free* [*Free Regsitration Required]
Uploader: Shaktiktilar

Proceed to Checkout Continue Shopping. We have no amendments or corrections for this wstm. Today, some 12, ASTM standards are x1244 around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. If the manhole fails the initial test, it may be repaired by an approved method until a satisfactory test is obtained.

I hope this explanation helps clarify the procedure a bit. If we were to round up to a foot depth of bury, we would need the mercury to hold for at least 40 seconds. For your example, this length of time must be greater than or equal to asym seconds for the manhole to be accepted. Already Subscribed to this document. Vacuum testing backfilled manhole systems is not recommended, especially in the presence of ground water. Internal Pressure at Critical Depth Vacuum pressure.

Note 1Vacuum test criteria presented in this test method are similar to those in general use. The test and criteria have been widely and successfully used in testing manholes. Remember me for one month. The resolution to this problem is to perform a vacuum test prior to backfilling and, if necessary, again after backfilling. You may delete a document from your Alert Profile at any time.

  AL MASUDI MEADOWS OF GOLD PDF

This test method is used for testing concrete manhole sections utilizing mortar, mastic, or gasketed joints. Note 1—Vacuum test criteria presented in this test method are similar to those in general use.

V1244 a Reply Atm reply Your email address will not be published. Copyright Compu-tecture, Inc. Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards.

Your email address will not be published. Note 1 – Vacuum test criteria presented in this test method are similar to those in general use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Vacuum Testing Precast Concrete Manholes

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Vacuum test criteria presented f1244 this test method are similar to those in general use. In your example, if we round down to a foot depth of bury, we would need the mercury to hold for at least 35 seconds. Users are hereby cautioned that misuse or misapplication of the test criteria contained herein can cause permanent damage to the system being tested.

This standard is also available to be included in Standards Subscriptions. If ground water is present, use the following information to determine if a reduction in vacuum pressure is warranted:. Many people do not fully understand the effects of vacuum testing backfilled manhole systems in the presence of ground water. Need more than one copy?

  BOY CULTURE MATTHEW RETTENMUND PDF

Vacuum Testing Precast Concrete Manholes

Please first verify your email before subscribing to alerts. Already Subscribed to this document. For more information Click Here Vacuum testing is a quick, safe and practical way to validate manhole system integrity. Testing after backfilling provides a degree of certainty that a watertight system has been installed. To determine the actual loads induced on a backfilled structure, use the following information in addition to the actual in-place soil properties to properly calculate the effective stress at the critical location.

Your Alert Profile lists the documents that will be monitored. Depth to bottom-most critical connector With this information, you can determine that the theoretical in-place loads experienced by the deepest connector as outlined in the following example. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Are you sure you want to empty the cart?

This standard is not included in any packages. As the voice of the U.